The 7702BPX-IF-B50 2x1 RF protection switches for IF frequencies provide automatic changeover functionality to provide bypass protection for RF signals from 10MHz to 850MHz. Typical applications include main/standby failover protection for 70/140MHz uplink applications. When used for automatic changeover, the 7702BPX-IF have a MAIN input and a STANDBY input. It will automatically switch to the Standby input when the Main input power is weak or lost. Switch back to the Main input when the signal is re-established may be configured to happen automatically or manually. The 7702BPX-IF occupy one card slot and can be housed in the 1RU 7801FR frame which holds up to four single or two dual slot modules, the 3RU 7800FR frame which has a 15 slot capacity, the portable 3RU 350FR frame which has a 7 slot capacity, or a standalone enclosure which holds a single module.
Intelligent auto switching with input power detection
User definable threshold levels on 7703BPXA-IF version
Maintains switch state and RF channel on loss of power to card or frame
Supports automatic or manual control via GPI or SNMP on 7703BPXA-IF
Switch state indication via GPO
Card edge LEDs indicate active input channels, output channel and power levels below threshold
Fully hot swappable from front of frame
Wide operating frequency range, 10MHz to 850MHz
Comprehensive signal and card status monitoring via four digit card edge display or remotely through SNMP and VistaLINK® capability on 7703BPXA-IF version
Spec Sheet available - Yes
Input Impedance:
75 ohm
Number of Inputs:
2
Number of Outputs:
1
Output Impedance:
75 ohm
Active Power:
3 Watt
DC Voltage:
12 Volts
RF I/O Connector:
BNC per IEC 61169-8 Annex A
RF I/O I/O Impedance:
75 ohm (50 Ohm optional)
RF I/O Frequency Response(< ±0.25dB):
10 to 200 MHz
RF I/O Frequency Response(< ±0.5dB):
10 to 850 MHz
RF I/O Insertion Loss:
< 4 dB
RF I/O Return Loss at 10MHz to 200MHz:
> 15 dB
RF I/O Return Loss at 10MHz to 850MHz:
> 12 dB
RF I/O Isolation:
> 45 dB
RF I/O Input Power Range:
0 to -50 dBm
General Purpose Input Type:
Opto-isolated, active low with internal pull-ups to +5V
General Purpose Input Connector:
2 pins plus ground on 6 pin terminal strip
General Purpose Input Signal Level(+5V Pullup):
Low: -5V to +2.5V DC, High: 3.5V to 10V DC
General Purpose Input Signal Level(+12V Pullup):
Low: -5V to +9.5V DC, High: 10.5V to 15V DC
Maximum Sink Current:
15 mA (input shorted to ground)
Maximum Leakage Current for Input High:
200 microAmps
General Purpose Output Type:
"Dry Contact" relay contacts - normally open & normally closed contact provided
General Purpose Output Connector:
3 pins on 6 pin terminal strip